Data acquisition unit (DAQ) TVR 60-8A |
| - |
Analog to digital conversion of slowly changing positive current signals on 60 current channels. |
| - |
Measuring of angular move of two phase draw works revolutions sensor. |
| - |
Measuring of frequency on eight channels (pulse/sec) with further conversion of the obtained values into current or voltage. |
| - |
Definition of conditions on eight channels. |
| - |
Closing-unclosing of normally open "dry" contacts on eight channels. |
| - |
Power supply to sensors (barriers) + 24V. |
| - |
Digital data transfer to the unit computer via RS-422/485 interface in conformity with the exchange protocol. |
| - |
Data acquisition unit is equipped with the keyboard beeper and a password protection against unauthorized change of data. |
|
| |
Technical Data: |
| Supply voltage DC: 5V "from USB or external power supply". |
| Power Consumption: max. 7.5 VA. |
| Interface between PCB and computer: USB cable "male/male". |
| Max. input frequency "Freq. channels": 1 KHz. |
| Operation temperature : up to 50°C. |
|
|
|
|
| |
|
|
Display Recorder "touch screen" |
| It is a chartless high-end display recorder in 300 mm x 300 mm format with 12.1" Color- TFT-Display.
|
| Power consumption: max 7.5 VA. |
|
|
Channels :
Up to 48 analog channels and up to 48 digital . |
|
| Specifications : |
| - |
Fast scanning rate of 20 / 125 / 500 m-sec. |
| - |
70 MB upwards to 1.85 GB internal data buffer. |
| - |
Considerably math functions Interfaces: Ethernet, RS 485 Mod-bus, USB, slot for CF card. |
| - |
Data logging via USB Interface or by CF card. |
| - |
Touch screen with rapid navigation. |
| - |
Configuration on device or by way of SIREC D manager or server software. |
| - |
Firmware options individual selectable by a flexible credit system.
|
|
|
|
|
|
| |
 |
|
Recorder Transokomp 350
Transokomp 350 is configurable microprocessor multipoint data recorder for up to 30 channels. Connection of thermocouples, resistive sensors and voltage transducers is direct. Whereas current signals are connected via external shunts. Measuring ranges and sensor types can be configured easily via the built-in key panel.
The raster scan method and the improved dot-matrix printing system permits recording of max.30 channels plus 30 additional calculated values in 2 seconds. This simultaneous recording optimizes the accuracy and ensures reliable data analysis. For optimizing data evaluation, there are optional arithmetic functions with them Transokomp 350 can execute analyses for which other recorders require a separate computer.
The input signals can be DC voltage or current, thermocouples, resistance and logic signals.
Input module :
universal (DC voltage, RTD, TC. DI), DCV/TC/DI. (Dedicated input)
Communication interface module :
RS-232-C
|
|
|
| |
 |
|
PetroServices DAQ PRO
Petroservices DAQ "data pro (it is a backup DAQ) This DAQ is mainly an electronic board that implements the functions of a complete data acquisition system.
This PCB can deal with the following inputs :
40 analog channels 8 frequency channels "0-1 KHz" 4 up/down counter channels
All the inputs are connected to PCB via 3 flat cables "1" for digital inputs and "2" for analog inputs. The PCB is connected to computer by a USB cable "male/male" and transmits all data to computer using the software included with DAQ.
Technical Data :
|
| |
|
| Supply voltage DC: 5V "from USB or external power supply". |
| Power Consumption: |
| Interface between PCB and computer: USB cable "male/male". |
| Max. input frequency "Freq. channels": 1 KHz. |
| Operation temperature : up to 50°C. |
|
|
|
| |
|
|
|
| |
|
 |
|
| |
- |
Display unit with analogue output for different operation modes. |
| |
- |
Tachometer, frequency meter. |
| |
- |
Counter for positions and events. |
| |
- |
Baking time, processing time (reciprocal speed). |
| |
- |
Timer, stopwatch. |
| |
- |
Speed display from delay between start/stop inputs. |
| |
- |
Typical application for PetroServices MLU: it works as an up/down counter with the draw work sensor with digital display and analog output fed to the data acquisition system which delivers these data into the online system to specify the depth and rate of penetration "ROP" on PetroServices software. |
|
|
|
|
|
|
|
| |
|
 |
|
The universal frequency converter (UFC) is a device that converts input pulses "freq. signal" into analog output current or voltage. The device is marked with "Ex" so, it's suitable for the connection of field devices used in potentially explosive atmospheres..
Field circuits for this device are intrinsically safe and are galvanic isolated from non-intrinsically safe circuits. The device thus establishes an electromagnetic separation between the potentially explosive atmospheres and the safe areas in a system.Typical applications for the universal frequency converter (UFC) are SPM and RPM measurements.
|
|
|
|
|
|
|
| |
|
| |
|
| |
|
|
|
|
|
|